CONTACT RATING: From low level* to 10.1 AMPS @ 250 V AC.
ELECTRICAL LIFE: 100,000 cycles
INSULATION RESISTANCE: 1,000 M ohm min.
DIELECTRIC STRENGTH: 1,000 Vrms min. @ sea level.
OPERATING TEMPERATURE: –17ºF to 185ºF (–25ºC to 85ºC).
OPERATING FORCE: From 142 to 170 grams at actuator button.Forces are less at free end of lever actuators; (see OPERATING FORCE and ACTUATOR option sections).
MOUNTING: 2-56 screws, torque 2.3 in/lbs max.
Low Level=conditions where no arcing occurs during switching, i.e., 0.4 VA max. @ 20 V AC or DC max.
Materials
SWITCH HOUSING: Thermoplastic polyester or high temperature thermoplastic (PTS) (UL 94V-0).
MOVABLE CONTACTS: Fine silver for ratings greater than 1 AMP @ 125 V
AC. Fine silver with 24K gold plate for 1 AMP @ 125 V AC or less.
STATIONARY CONTACTS: Fine silver welded on copper alloy for ratings
greater than 1 AMP @ 125 V AC. Gold alloy welded on copper alloy for
ratings less than 1 AMP @ 125 V AC.